46
rev. 7-2017 114A3873.D
Wireless Door Alarm System
Setting Up the Controller
To ensure that the multiplexer operates properly, it must be set up
in the access control system as a multiplexer.
With the correct version of firmware, use the
Setup Remotes
function to configure the remote. The controller refers to the
remote devices only by the address on the RS485 line.
For the wireless multiplexer, configure the remote in the controller
to be a multiplexer.
The controller only refers to doors by the multiplexer and channel
number assigned to it, not the physical location or unit number
This cross-reference table turns multiplexer and channel numbers,
as read by the controller, into unit numbers which are used in
reported event messages on-screen.
This programmed reference table is the only way an end-user can
physically locate remote devices on their site when the controller
reports an event.
If using a Falcon base unit system, make sure the controller
firmware is at least Version 4.10.
The most important step in the installation process is
programming a cross-reference table on the system between
the physical door/unit numbers on-site, the multiplexer
number, and channel number.
It it good practice to
copy this information and leave it in more
than one location
(one with the installer, one at the site etc.) for
future reference. Should the system need to be reprogrammed,
it is very hard to recreate this data.