Wireless Door Alarm System
9
114A3873.D rev. 7-2017
Door Jamb Mounting Instructions
1
Apply PL Premium
®
construction adhesive to the back of the
magnet. Align the center of the magnet with the narrow mark
on the side of the mounting plate facing the door and rivet
the magnet to the door no more than ½ inch away from the
mounting plate. See page 5 for more information.
2
Apply PL Premium
®
construction adhesive to the back of the
mounting plate and use two wall anchors and two #8 x 1” flat
head screws to fasten the mounting plate.
3
Position the box bottom with the magnet alignment mark
facing toward the door and fasten the wireless box bottom to
the mounting plate using two 6-32 x 3/8” pan head screws.
4
Place the PC board in the box bottom and hold in place until
the box cover is in place.
5
Fasten the box cover to the box bottom using two #6 x 1-½”
flat head screws
.
If placing the wireless box on the door jamb interferes with
the travel of the toe plate and/or the door handle, use the
Door Header Mounting Instructions instead on page 11
Application Note: Always use PL Premium® adhesive on
the magnet and the mounting plate. The box assembly
should be mounted as high as possible on the jamb to
prevent damage