50
rev. 7-2017 114A3873.D
Wireless Door Alarm System
•
Unit Comm. On 0001
Indicates that a transmitter has begun reporting to a multiplexer after it
has been off.
•
The numbers following the message are the transmitters’ registered
channel numbers.
•
The controller looks up the channel number in the cross-reference table.
•
If the channel is not assigned, the event reports as Unknown Check in
Restore with a reference to the multiplexer and channel numbers.
•
If the channel is assigned, the event will report as Unit Check in Restore
with a reference to the unit number.
•
The actual reporting of the event depends on the configuration of the
controller.
•
Unit Comm. Off
0001
Warns that a transmitter has not reported in the required time.
•
Each transmitter is scheduled t report to the multiplexer within a fixed
amount of time.
•
If a transmitter fails to report, the multiplexer records this event and sends
it to the controller.
•
The numbers following the message are the transmitter’s registered
channel numbers.
•
The controller looks up the channel number in the cross-reference table.
•
If the channel is not assigned, the event reports as Unknown Check in Fail
with a reference to the multiplexer and channel numbers.
•
If the channel is assigned, the event will report as a Unit Check in Fail with a
reference to the unit number. Depending on the settings in the controller,
this event can also sound the alarm siren.
•
To get attention, the multiplexer sends this notification to the controller
every four hours until the problem is corrected.