C1 Pre-Assembly of Brackets
Assembly
1. Position spacer tube Ø26 (3.1) of the
Spacer M20 (3) in the Climbing Rail
RCS with the help of a hammer.
2. Insert bolt M20×120 (3.2) through
the holes Ø21 of the Climbing Rail
and through the spacer tube.
3. Attach self-locking nut M20-8 (3.3)
to the bolt and tighten. Tightening
torque min. 100 Nm.
(Fig. C1.01)
Spacers M20 (Climbing Bolts) must
not be moved in the Climbing Rail,
but additionally installed. The stroke
of the climbing device allows a maxi-
mum distance of 50 cm from the
Spacers.
It could be necessary to release the
adjacent Spacers in the Climbing
Rail. After mounting the additional
Spacer, re-tighten all previously loos-
ened bolts. Tightening torque min.
60 Nm.
Have the nuts (3.3) been tightened?