Chapter 6 Description of Function Codes
2:RS485 communication control
Commands are given from host computer. Refer to Group F13: Communication Parameters
for parameters.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F00.03
Max.output frequency
50.00Hz
~
600.00Hz
50.00Hz
●
It is used to set the maximum output frequency of the inverter. It is the basis of the frequency
setting, as well as the foundation of acceleration and deceleration speed. Please pay attent-
ion.
When analog input,pulse input(HDI),multiple command as frequency source of FC280, it
100% corresponding to F00.03.
Upper limit of the inverter’s output frequency. The value should be less than or equal to the
maximum
output frequency.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F00.04
Run frequency upper
limit
F00.05
~
F00.03( max.frequency)
50.00Hz
※
Lower limit of the inverter’s output frequency.
When the set frequency is lower than the lower limit frequency:When the starting set frequen
cy is lower than the lower limit of frequency, it can not be started.When the set frequency
entering the running frequency is lower
than the lower
limit
frequency,AC drive can stop,run
as frequency lower limit or zero speed via F09.14.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F00.05
Run frequency lower
limit
0.00Hz
~
F00.04(run frequency
upper limit)
00.00Hz
※
Function
code
Name
Description
(setting range)
Factory
Default
Change
F00.06
Frequency A
command selection
0:keypad, no retentive upon power
failure
1:keypad, retentive upon power
failure
0
●
C
h
a
p
te
r
6