1: Keep final values after the AC drive runs one cycle
The AC drive keeps the final running frequency and direction after running one cycle.
2: Repeat after the AC drive runs one cycle
The AC drive automatically starts another cycle after running one cycle, and will not stop until
receiving the stop command.
Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
F12.01
Simple PLC retentive
selection
Unit's digit: Retentive upon
power failure
0: No
1: Yes
Ten's digit: Retentive upon
stop
0: No
1: Yes
00
※
PLC retentive upon power failure indicates that the AC drive memorizes the PLC running
moment and running frequency before power failure and will continue to run from the memo-
rized moment after it is powered on again. If the unit's digit is set to 0, the AC drive restarts
the PLC process after it is powered on again.
PLC retentive upon stop indicates that the AC drive records the PLC running moment and
running frequency upon stop and will continue to run from the recorded moment after it starts
up again. If the ten's digit is set to 0, the AC drive restarts the PLC process after it starts up
again.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F12.02
Multi-speed 0
-100.0%
~
100.0%
0.0%
※
F12.03
Multi-speed 1
-100.0%
~
100.0%
0.0%
※
F12.04
Multi-speed 2
-100.0%
~
100.0%
0.0%
※
F12.05
Multi-speed 3
-100.0%
~
100.0%
0.0%
※
F12.06
Multi-speed 4
-100.0%
~
100.0%
0.0%
※
F12.07
Multi-speed 5
-100.0%
~
100.0%
0.0%
※
F12.08
Multi-speed 6
-100.0%
~
100.0%
0.0%
※
-184-