Function
code
Name
Description
(setting range)
Factory
Default
Change
F10.24
Maximum deviation
between two PID outputs
in reverse direction
0.00%
~
100.00%
1.00%
※
F10.25
PID integral property
Unit's digit :Integral
separated
0: Invalid
1: Valid
Ten's digit :Whether to stop
integral operation when the
output reaches the limit
0: Continue integral
operation
1: Stop integral operation
00
※
F10.26
Detection value of PID
feedback loss
0.0%: Not judging feedback
loss 0.1%–100.0%
0.0%
※
F10.27
Detection time of PID
feedback loss
0.0s
~
20.0s
0.0s
※
F10.28
PID operation at stop
0: No PID operation at stop
1: PID operation at stop
0
※
Group F11: Swing Frequency, Fixed Length and Count
F11.00
Swing frequency setting
mode
0: Relative to the central
frequency
1: Relative to the maximum
frequency
0
※
F11.01
Swing frequency
amplitude
0.0%
~
100.0%
0.0%
※
F11.02
Jump frequency
amplitude
0.0%
~
50.0%
0.0%
※
F11.03
Swing frequency cycle
0.1s
~
3000.0s
10.0s
※
F11.04
Triangular wave rising
time coefficient
0.1%
~
100.0%
50.0%
※
F11.05
Set length
0m
~
65535m
1000m
※
F11.06
Actual length
0m
~
65535m
0m
※
Chapter 5 Function & Parameter Table
-76-
C
h
a
p
te
r
5
Peaco Support FC280 Series VFD User Manual