Chapter 8 Appendix
-234-
C
h
a
p
te
r
8
5. Photovoltaic Pump Special Function Parameter Table
Function
code
Name
Description
(setting range)
Factory
Default
Group F0
F0.00
Speed Control
Mode
0: No PG vector control (SVC);
1: PG vector control (FVC);
2: V/F control
2
F0.04
Upper limit of
operating
frequency
F0.05~100% F0.04 is used to limit the
maximum value of the target frequency.
The final target frequency after PI
adjustment cannot exceed the set upper
limit value.
50.00Hz
F0.05
Operating
frequency lower
limit
The 0.0%~F0.04 F0.05 is used to limit the
minimum value of the target frequency, and
the final target frequency can not be lower
than the set limit after the PI adjustment.
10.00Hz
F0.06
Frequency
instruction
selection
0: The keyboard is set, and the power
failure of the inverter is not memorized;
1: The keyboard is set, and the inverter is
powered off;
2: The analog AI1 setting;
3: The analog AI2 setting;
4: The analog AI3 setting ;
5: PULSE pulse setting (HDI);
6: Multi-speed operation setting;
7: Simple PLC setting;
8: PID control setting;
9:485 communication setting;
10: Panel potentiometer given.
8
Group F9
F9.50
Awakening
frequency
Sleep frequency (F08.52) ~ maximum
frequency (F00.03); In sleep state, and the
current running command is valid, when the
PID calculation target frequency is greater
than F8.50 wake-up frequency, after F8.51
delay time, Inverter wake up start
20Hz
Peaco Support FC280 Series VFD User Manual
www.peacosupport.com [email protected] Free Shipping Worldwide Reliable Supplier