Chapter 6 Description of Function Codes
Function
code
Name
Description
(setting range)
Factory
Default
Change
F11.07
Number of pulses per meter 0.1
~
6553.5
100.0
※
The preceding parameters are used for fixed length control.
The length information is collected by multi-function digital input(DI) terminals. F11.06 (Actual
length) is calculated by dividing the number of pulses collected by the DI terminal by F11.07
(Number of pulses each meter).
When the actual length F11.06 exceeds the set length in F11.05, the multi-function digital
output terminal allocated becomes ON.
During the fixed length control, the length reset operation can be performed via the multi-
function S terminal allocated with function 28. For details, see the descriptions of F06.00 to
F06.09.
Allocate corresponding input terminal with function 27 (Length count input) in applications. If
the pulse frequency is high, HDI must be used.
Function
code
Name
Description
(setting range)
Factory
Default
Change
F11.08
Set count value
1
~
65535
1000
※
F11.09
Designated count value
1
~
65535
1000
※
The count value needs to be collected by input terminal. Allocate the corresponding input
terminal with function 25 (Counter input) in applications. If the pulse frequency is high, HDI
must be used.
When the count value reaches the set count value (F11.08), multi-function digital output ter-
minal allocated with function 8 (Set count value reached) becomes ON. Then the counter
stops counting.
When the counting value reaches the designated counting value (F11.09), multi-function
digital output terminal allocated with function 9 (Designated count value reached) becomes
ON. Then the counter continues to count until the set count value is reached.
F11.09 should be equal to or smaller than F11.08.
Designated count relay
Count pulses input HDI
Set count MO1
1
2
3
4
5
6
7
8
9
Fig.6-33 Reaching the set count value and designated count value