Parameter Reference
15-13
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
F627
Current Limiting when Flycatching
50-200
100
╳
F631
VDC Adjustment Selection
0: Disabled
1: Enabled
0
√
F632
Target voltage of VDC adjustor (V)
200-800
Subject to
inverter
model
√〇
F633-
F637
Reserved
F638
Parameters copy enabled
0: Copy forbidden
1: Parameters copy 1
(voltage level and power rating are
totally same)
2: Parameters copy 2
(without considering voltage level
and power rating)
1
√
F639
Reserved
F640
Parameter copy type
0: Copy all parameters
1: Copy parameters
(except motor parameters from
F801 to F810/F844)
1
√
F641-
F649
Reserved
F650
High-frequency performance
Setting range:
0: Invalid
1: Terminal enabled
2: Enabled mode 1
3: Enabled mode 2
2
×〇
F651
Switchover frequency 1
F652-150.00
100.00
√〇
F652
Switchover frequency 2
0-F651
95.00
√〇
F653-
F670
Reserved
Timing Control and Protection: F700-F770
Function
Code
Function
Definition
Setting Range
Mfr’s Value Change
F700
Selection of terminal free stop mode
0: Immediate free stop (coast stop)
1: Delayed free stop (coast stop)
0
√
F701
Delay time for free stop and programmable
terminal action
0.0
~
60.0s
0.0
√
F702
Fan control mode
0: Controlled by temperature
1: Running when inverter is powered on
2: Controlled by running status
2
√
F703
Reserved
F704
Inverter Overload pre-alarm Setpoint (%)
50~100
80
╳
F705
Motor Overload pre-alarm Setpoint (%)
50~100
80
╳
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...