14.4.1 UL Standards
The UL/cUL mark applies to products in the United States and Canada and it means that UL
has performed product testing and evaluation and determined that their stringent standards
for product safety have been met. For a product to receive UL certification, all components
inside that product must also receive UL certification:
14.4.2 UL Standards Compliance
This drive is tested in accordance with UL standard UL508C, File No. E142140 and complies
with UL requirements. To ensure continued compliance when using this drive in combination
with other equipment, meet the following conditions:
1. Do not install the drive to an area greater than pollution severity 2 (UL standard).
2. Installation and operating instructions shall be provided with each device.
The following markings shall appear in one of the following locations; shipped separately
with the device; on a separable, self-adhesive permanent label that is shipped with the
device; or anywhere on the device itself.
a) Designation markings for each wiring diagram.
b) Markings for proper wiring connections.
c) “Maximum surrounding air temperature 40
o
C” or equivalent.
d) “Solid state motor overload protection reacts when reaches 150% of FLA” or
equivalent.
e) “Install device in pollution degree 2 environment.” Or equivalent.
f) “Suitable for use on a circuit capable of delivering not more than 5,000 rms
symmetrical amperes, 480/240 volts maximum when protected by made by COOPER
BUSSMANN LLC Class T Fuse.” Or equivalent. Recommended input fuse selection
listed below:
Frame Size or Model
Fuse Model
Fuse Current Rating
10G-31-0015-XX
10G-31-0025-XX
10G-31-0035-XX
10G-31-0045-XX
JJS-15
15A
10G-32-0050-XX
10G-32-0070-XX
10G-32-0100-XX
JJS-25
25A
10G-11-0015-XX
10G-11-0025-XX
10G-11-0035-XX
10G-11-0045-XX
JJS-15
15A
10G-12-0050-XX
10G-12-0070-XX
10G-12-0010-XX
JJS-25
25A
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...