Parameter Reference
15-9
AC10 Inverter
Analog Input and Output: F400-F480
Function
Code
Function
Definition
Setting Range
Mfr’s Value Change
F400
Lower limit of AI1 channel input
0.00
~
F402
0.01
√
F401
Corresponding setting for lower limit of AI1
input
0
~
F403
1.00
√
F402
Upper limit of AI1 channel input
F400
~
10.00
10.00
√
F403
Corresponding setting for upper limit of AI1
input
Max
(
1.00
,
F401
)~
2.00
2.00
√
F404
AI1 channel proportional gain K1
0.0
~
10.0
1.0
√
F405
AI1 filtering time constant
0.01
~
10.0
0.10
√
F406
Lower limit of AI2 channel input
0.00
~
F408
0.01V
√
F407
Corresponding setting for lower limit of AI2
input
0
~
F409
1.00
√
F408
Upper limit of AI2 channel input
F406
~
10.00
10.00V
√
F409
Corresponding setting for upper limit of AI2
input
Max
(
1.00
,
F407
)~
2.00
2.00
√
F410
AI2 channel proportional gain K2
0.0
~
10.0
1.0
√
F411
AI2 filtering time constant
0.01
~
10.0
0.10
√
F418
AI1 channel 0Hz voltage dead zone
0
~
0.50V (Positive-Negative)
0.00
√
F419
AI2 channel 0Hz voltage dead zone
0
~
0.50V (Positive-Negative)
0.00
√
F421
Panel selection
0: Local keypad panel
1: Remote control keypad panel
2: Local remote control
keypad
1
√
F422
Reserved
F423
AO1 output range
0
:
0
~
5V
;
1
:
0
~
10V or 0-20mA
2: 4-20mA
1
√
F424
AO1 lowest corresponding frequency
0.0
~
F425
0.05Hz
√
F425
AO1 highest corresponding frequency
F424
~
F111
50.00Hz
√
F426
AO1 output compensation
0
~
120
100
√
F427
AO2 output compensation
0: 0
~
20mA
1: 4
~
20mA
0
√
F428
AO2 lowest corresponding frequency (Hz)
0.0
~
F429
0.05
√
F429
AO2 highest corresponding frequency (Hz)
F428
~
F111
50.00
√
F430
AO2 output compensation (%)
0
~
120
100
√
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...