13-5
The Default Applications
AC10 Inverter
Two Run inputs and two Set-point inputs are provided. The Auto/Manual switch selects which
pair of inputs is active. The Application is sometimes referred to as Local/Remote.
Function setting
Setting value
F228 Macro selection
2: Auto/manual control
F106 Control mode
2: VF control
F203 Main frequency source X
1: AI1
F204 Accessorial frequency source Y
2: AI2
F207 Frequency source selecting
2: X or Y
F316 DI1 terminal function setting
56: Manual running
F317 DI2 terminal function setting
57: Auto running
F318 DI3 terminal function setting
55: Auto /manual switchover
F319 DI4 terminal function setting
58: Direction
F320 DI5 terminal function setting
8: Free stop
F431 AO1 analog output signal selecting
0: Running frequency
Coast stop
1
2
3
5
6
4
7
8
9
10
11
12
13
14
15
16
17
18
TA
TB
TC
1
DO
24
V
CM
DI1
DI2
DI3
DI4
DI5
10
V
1
AI
2
AI
GND
1
AO
A
B
REF
Direction
Auto/manual
select
Manual run
Auto run
Auto
setpoint
not used
not used
Analog output
F 431=0 , running
frequency is output
.
GND
Auto setpointAI 2 input 4- 20 mA
Manual setpoint AI1 input 0- 10V
10V
Coast stop
Direction
Auto / manual select
Manual run
Auto run
CM
24V
not used
Relay output
The function is valid,
inverter runs reverse
.
The function is valid,
manual run is selected.
F 300=1 , inverter outputs
fault signal.
Содержание 10G-46-0600-BF
Страница 2: ......
Страница 18: ...Installation 3 3 AC10 Inverter 3 3 Inverters Installed in a Control Cabinet...
Страница 26: ...Installation Connection 7 2 AC10 Inverter Metal Cover Layout Frames 6 11...
Страница 112: ...The Default Applications 13 2 AC10 Inverter 13 1Application 1 Basic Speed Control F228 1...
Страница 114: ...The Default Applications 13 4 AC10 Inverter 13 2 Application 2 Auto Manual Control F228 2...
Страница 116: ...The Default Applications 13 6 AC10 Inverter 13 3 Application 3 Preset Speeds F228 3...
Страница 118: ...The Default Applications 13 8 AC10 Inverter 13 4 Application 4 Raise Lower Secondary F228 4...
Страница 120: ...The Default Applications 13 10 AC10 Inverter 13 5Application 5 PID F228 5...