C. Cross-Connecting Ports

8799-A2-GB20-10

April 2003

C-21

Time Slot Assignments – DSL Port 6 

TS01

Port Type
(D = DSL

(

G = G.703)

Port Number

(1–8)

Time Slot

(1–31)

d (Data) or v (Voice)

TS01

TS02

TS03

TS04

TS05

TS06

TS07

G

G

G

G

G

G

G

TS08

TS09

TS10

TS11

TS12

TS13

TS14

G

G

G

G

G

G

G

TS15

TS16

TS17

TS18

TS19

TS20

TS21

G

G

G

G

G

G

G

TS22

TS23

TS24

TS25

TS26

TS27

TS28

G

G

G

G

G

G

G

TS29

TS30

TS31

G

G

G

Содержание Hotwire 8799

Страница 1: ...Hotwire 8799 TDM SHDSL Line Card with G 703 Interface User s Guide Document No 8799 A2 GB20 10 April 2003...

Страница 2: ...es representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor...

Страница 3: ...upport 1 6 2 Using the Asynchronous Terminal Interface User Interface Access 2 1 Management Serial Port Settings 2 1 ATI Access Levels 2 2 Menu Hierarchy 2 4 Screen Work Areas 2 5 Navigating the Scree...

Страница 4: ...rror Statistics 4 9 Viewing DSL Performance Statistics 4 11 Viewing G 703 Performance Statistics 4 13 Viewing Current DSL Performance 4 15 Viewing Inband Management Statistics 4 17 Viewing LED Status...

Страница 5: ...Setting Cross Connect Mode A 21 Assigning Time Slots A 23 Management and Communication Menu A 27 General SNMP Management Options A 27 SNMP NMS Security Options A 30 SNMP Trap Options A 32 Inband Manag...

Страница 6: ...Contents iv April 2003 8799 A2 GB20 10 D Connector Pin Assignments Overview D 1 Front Panel 50 pin DTE Connector Pinouts D 1 E Technical Specifications Index...

Страница 7: ...g the user interface and navigating the screens Chapter 3 Initial Startup and Configuration Provides procedures for setting up the user interface and configuring the card Chapter 4 Monitoring the Card...

Страница 8: ...physical and regulatory specifications network and port interfaces power consumption values and accessory part numbers Index Lists key terms acronyms concepts and sections in alphabetical order Secti...

Страница 9: ...l 2 048 Mbps or fractional payload rates over a 2 wire full duplex circuit over varying distances based on the conditions of the 2 wire loop Examples include support for router multiplexer and PBX con...

Страница 10: ...nal or PC via the Management Serial port of the DSLAM Network Management System NMS via the Management MCC port of the DSLAM through the line card s 10BaseT port Remote Management Provides remote mana...

Страница 11: ...HDSL Transceiver Unit Central Site STU R SHDSL Transceiver Unit Remote Terminal Site Figure 1 1 Sample STU C to STU R Configuration Figure 1 2 Sample Campus Configuration shows line cards used to dist...

Страница 12: ...5 6 7 PO RT S 4 8 TDM SDSL 8779 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8 TDM SHDSL 8799 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8 TDM SDSL 8779 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S...

Страница 13: ...2 3 5 6 7 PO RT S 4 8 TDM SHDSL 8799 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8 TDM SDSL 8779 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8779 8799 8779 8799 8 Users Data x 64 Kbps 512 Kbps 512...

Страница 14: ...s SHDSL MIB draft ietf adslmib hdsl2 txt Supports SHDSL configuration status statistics and tests SNMP Trap Support The Hotwire 8799 Line Card supports traps as defined in RFC 1215 They may include va...

Страница 15: ...stem NMS connected to a LAN WAN port on the DSLAM Telnet session through the Embedded Operations Channel EOC NOTE Only one ATI session can be active at a time to each line card and another user s sess...

Страница 16: ...Administrator status To provide login security to the DSL system user accounts must be configured NOTE There must be at least one Administrator configured in order to have system security For informat...

Страница 17: ...r Data selection criteria What you entered in previous screens main Access Level Administrator Slot 4 Model 8799 MAIN MENU Status Test Configuration Control Ctrl a to access these functions Exit LOS a...

Страница 18: ...ault Factory Configuration Configuration Loader Current Configuration G 703 Copy Ports System Options Cross Connect Change Identity Download Code Apply Download Port LEDs DSL G 703 Tests Device Tests...

Страница 19: ...This is the area below the dotted line that lists function keys specific to the screen field value choices and system messages displays the highest level alarm from the Health and Status screen main c...

Страница 20: ...ssage area below the dotted line at the bottom of the screen Esc Return to the previous screen Tab Move cursor to the next field on the screen Backspace Move cursor to the previous field on the screen...

Страница 21: ...cebar to scroll through other valid values Press Enter to select the value Function Keys All function keys located below the dotted line operate the same way upper or lowercase throughout the screens...

Страница 22: ...press the Tab key until you reach the desired function key Example To save the current options type s or S Save 3 Press Enter The function is performed 4 To return to the screen area above the dotted...

Страница 23: ...ter If you have accessed the card through the MCC the Hotwire Chassis Card Selection menu appears Exiting From the DSLAM Session You can manually log out of the system or after five minutes of inactiv...

Страница 24: ...2 Using the Asynchronous Terminal Interface 2 10 April 2003 8799 A2 GB20 10...

Страница 25: ...estore access to the ATI and reset the card These procedures include Entering Identity Information on page 3 2 Configuring the Card on page 3 3 Current and Default Factory Configurations Configuration...

Страница 26: ...ld The SNMP System entry fields are System Name The general SNMP system name System Location The physical location of the SNMP managed device System Contact Identification information such as contact...

Страница 27: ...s area below the dotted line 5 Select Save and press Enter Command Complete appears Configuring the Card Configuration option settings determine how the line card operates Use the Configuration menus...

Страница 28: ...ection sequences contained in this manual Current Configuration is assumed and shown If you select Then Current Configuration The selected configuration option set is loaded and the Configuration Edit...

Страница 29: ...terface Copy Ports Copy Ports Options Table A 5 DSL network and G 703 interface ports by copying options from port to port System Options System Options Table A 6 General system options of the card Sy...

Страница 30: ...ional suffix of up to three characters The system will automatically upload the configuration file and create directories and filenames as needed UNIX machine If your server is hosted by a UNIX machin...

Страница 31: ...Site STU R position the cursor in the Destination field Use the spacebar to select a network destination for the TFTP server Select DSL if the TFTP server destination is the DSL link port or IMC Inter...

Страница 32: ...ssion to disconnect Do not answer Yes unless you are prepared to disconnect If the DSL Mode configuration option is changed the Save Configuration screen bears the warning that an answer of Yes will c...

Страница 33: ...he TFTP Server IP Address field Enter the TFTP server IP address or M1 for the MCP FFS The first three digits of the IP address cannot be 000 or greater than 223 3 For an STU C go on to Step 4 For an...

Страница 34: ...re 1 Press the Escape key to return to the Control menu Select Apply Download 2 On the Apply Download screen type Yes to reset the card and activate the code Selecting Yes causes the line card to rese...

Страница 35: ...an STU C To access the DSL Interface Options screen follow this menu selection sequence Main Menu Configuration Current Configuration DSL Port To enable Adaptive Rate set the Min DSL Rate to a value...

Страница 36: ...ores the Default Factory Configuration 5 Enter Y at the prompt to confirm NOTE When you enter Y all data connectivity is interrupted You can also restore access to the user interface by reloading the...

Страница 37: ...rd operations Viewing System and Test Status on page 4 2 Health and Status Messages Self Test Results Messages Test Status Messages Performance Statistics on page 4 8 Viewing DSL Error Statistics View...

Страница 38: ...ges in priority order highest to lowest Refer to Table 4 1 Health and Status Messages Self Test Results Results of the Diagnostic test run on the device itself Refer to Table 4 2 Self Test Results Mes...

Страница 39: ...tative 2 Reset the card to clear the condition and message DLCI nnnn Down IBMC The DLCI is down for the Inband Management Channel 1 Verify DLCI and LMI on the router 2 Verify the G 703 connection Down...

Страница 40: ...ubleshoot the line DSL UAS Threshold Pt n The number of unavailable seconds for the DSL interface has reached or exceeded the configured threshold within a 15 minute interval 1 Disable the trap by set...

Страница 41: ...1 Verify that the network cable is securely attached at both ends 2 Verify proper STU R and STU C configuration 3 Contact network provider to troubleshoot the line LOS at G 703 Pt n An LOS Loss Of Si...

Страница 42: ...cking are also affected 1 Verify that the Secondary System Clock is properly configured See Table A 7 System Clock Options in Appendix A Configuration Options 2 Verify that the port configured for Sec...

Страница 43: ...the card s integrated circuit chips has failed device level testing Failure xxxxxxxx An internal failure occurred xxxxxxxx represents an 8 digit hexadecimal failure code for use by service personnel...

Страница 44: ...ear statistics Select PgUp or PgDn to view more statistics Select ClrNear or ClrFar to clear the near and far end statistics to zero For G 703 statistics select ClrStats to clear all statistics to zer...

Страница 45: ...mes unavailable after 10 contiguous SES Maximum value is 900 LOSWS Loss of Sync Word Seconds Seconds during which the SHDSL line had a Loss of Sync Word defect Maximum value is 900 main status perform...

Страница 46: ...is disabled Current Int Performance data for the current 15 minute interval Interval xx Historical performance data for up to 96 15 minute intervals 24 hours When blank the port is disabled Worst Int...

Страница 47: ...reference is the value needed to maintain a bit error rate of 10 6 XmtPw The transmit power level in dBm Atten The number of dB that the signal is below a reference point main status performance dsl_...

Страница 48: ...um value is 900 seconds 15 minutes This counter resets every 15 minutes Payload Rate The Payload Rate across the DSL interface DSL Line Rate The rate of the DSL line The line rate can be 200 2056 Kbps...

Страница 49: ...red Maximum value is 900 BES Bursty Errored Seconds Contains the number of bursty errored seconds for the current interval A bursty errored second is any second with more than one but less than 805 CR...

Страница 50: ...Current Interval Timer The number of seconds which have elapsed in the current 15 minute interval Maximum value is 900 seconds 15 minutes This counter resets every 15 minutes Error Events Counter A ru...

Страница 51: ...he transmit power level The following Current DSL Performance Statistics are collected for the selected port ES Errored Seconds Seconds during which one or more Cyclic Redundancy Check CRC errors or L...

Страница 52: ...Maximum value is 900 Fields on this screen include Field Contains Current Interval Timer The number of seconds which have elapsed in the current 15 minute interval Maximum value is 900 seconds 15 min...

Страница 53: ...s sent to the primary and backup IBMCs the number of octets sent to the DLCI and the number of octets sent to the LMI 0 4 294 967 295 The counts of DLCI and LMI octets are not displayed if Inband Mana...

Страница 54: ...nd Management Channel 16 1007 LMI The LMI Type configured for the Inband Management Channel Annex A Annex D or Standard Inband Management Type The type of Inband Management Channel configured for the...

Страница 55: ...ivity on the DSL network To view the LED status screen follow this menu selection sequence Main Menu Status Display LEDs The LED status display screen is updated every 5 seconds For information about...

Страница 56: ...Power On Self Test POST failure or an alarm was reported on a DSL or G 703 port No alarms Test Amber On Off Loopback test or POST is in progress No tests are active G 703 see NOTE below 1 8 Green On S...

Страница 57: ...r 3 Initial Startup and Configuration System Name The general SNMP system name System Location The physical location of the SNMP managed card System Contact Identification information such as contact...

Страница 58: ...serial number of the card Software Revision The software revision level of the firmware installed in the card Hardware Revision The hardware revision level of the main circuit card assembly in the ca...

Страница 59: ...DSL G 703 Tests Start and stop tests on the DSL or G 703 interface Device Tests Start and stop a lamp test Abort All Tests To abort all currently active user initiated tests excluding DSL initiated lo...

Страница 60: ...lumn displays the test duration Selecting Abort All Tests from the Test menu will not disrupt a network initiated loopback NOTES The Send and Monitor 511 test is not available in all firmware releases...

Страница 61: ...AIS is sent on the G 703 port Procedure To run a DSL Line Loopback 1 Position the cursor at the Start command next to DSL Loopback on the DSL G 703 Tests screen 2 Press Enter The Start command is cha...

Страница 62: ...er Loopback 1 Position the cursor at the Start command next to Repeater Loopback on the DSL G 703 Tests screen 2 Press Enter The Start command is changed to Stop Status is changed to Active 3 To manua...

Страница 63: ...the connected ports will be ignored Procedure To run a G 703 DTE Loopback 1 Position the cursor at the Start command next to G 703 DTE Loopback on the DSL G 703 Tests screen 2 Press Enter The Start c...

Страница 64: ...be used to verify the link Procedure To run a Remote Send Line Loopback 1 Position the cursor at the Up or Down selection next to Send Line Loopback on the DSL G 703 Tests screen 2 Press the spacebar...

Страница 65: ...and monitors a 511 pattern Acitivating a Send and Monitor 5111 test causes the EOC used for management to be lost to the remote unit Procedure To run a Send and Monitor 511 test 1 Allow the modem to f...

Страница 66: ...DeviceTests Lamp Test The Lamp Test determines whether all LEDs are lighting and functioning properly Procedure To test the LEDs 1 Position the cursor at the Start command next to Lamp Test on the De...

Страница 67: ...10 minutes Refer to Table A 6 System Options in Appendix A Configuration Options Command column Under the Command column on any test screen position the cursor at Stop next to the active test and pre...

Страница 68: ...5 Testing 5 10 April 2003 8799 A2 GB20 10...

Страница 69: ...bleshooting Overview There are many messages available to assess the status of the device and contribute to problem resolutions Refer to the following sections Configuring SNMP Traps on page 6 2 Devic...

Страница 70: ...rd To configure the card for SNMP traps use the SNMP Traps Options screen to Enable SNMP traps Select the type of SNMP traps to be sent from the card To configure SNMP Traps follow this menu selection...

Страница 71: ...sequence Main Menu Configuration Current Configuration Management and Communication General SNMP Management Refer to Table A 10 General SNMP Management Options in Appendix A Configuration Options to...

Страница 72: ...that configuration changes can be made Operator level users cannot make configuration changes Save the Login IDs Command Complete Action requested has successfully completed No action is needed Invali...

Страница 73: ...r the new login ID Please Wait Command takes longer than 5 seconds Wait until message clears Test Active A test is running and no higher priority health and status messages exist Contact service provi...

Страница 74: ...d Contact your service representative No power or the LEDs are not lit The card is not properly seated in the DSLAM Verify that the card is properly inserted There is no power to the DSLAM Verify that...

Страница 75: ...ld Trap Options Table A 3 Threshold traps for the Physical DSL port for STU C only G 703 Interface G 703 Interface Options Table A 4 G 703 interfaces 1 8 Copy Ports Copy Ports Options Table A 5 DSL ne...

Страница 76: ...pecified by the carrier Possible Settings Short Medium Long Default Setting Short The estimated line length is the estimated distance from the local exchange to determine the speeds that can be suppor...

Страница 77: ...oad Rates and DSL Line Rates for G 703 for information about maximum payload rates for different DSL line rates EIA 530 Payload Rate Possible Settings 64 128 Default Setting Highest multiple of 64 Kbp...

Страница 78: ...255 255 Specify the peer IP address The range for the first byte is 001 to 223 with the exception of 127 The range for the remaining three bytes is 000 to 255 Clear Sets the IP address to 00 000 000...

Страница 79: ...928 1856 29 1864 27 28 1864 1792 28 1800 26 27 1800 1728 27 1736 25 26 1736 1664 26 1672 24 25 1672 1600 25 1608 23 24 1608 1536 24 1544 22 23 1544 1472 23 1480 21 22 1480 1408 22 1416 20 21 1416 1344...

Страница 80: ...4 192 3 200 1 2 200 64 128 1 2 Table A 2 Payload Rates and DSL Line Rates for G 703 2 of 2 G 703 to G 703 G 703 to EIA 530 A DSL Line Rate Kbps Payload DSL Line Rate Kbps Payload Voice Mode Time Slots...

Страница 81: ...creen follow this menu selection sequence Main Menu Configuration Current Configuration DSL Port Threshold Traps main config dsl_trap Slot 4 Model 8799 Port 1 DSL THRESHOLD TRAP OPTIONS ES Trap Thresh...

Страница 82: ...Specifies the threshold for Unavailable Seconds events in a 15 minute interval after which a trap will be sent LOSW Trap Threshold Possible Settings 1 900 or 0 to Disable Default Setting 0 Specifies t...

Страница 83: ...rface Options screen follow this menu selection sequence Main Menu Configuration Current Configuration G 703 main config G 703 Slot 4 Model 8799 Port 3 G 703 INTERFACE OPTIONS Port Status Enable Frami...

Страница 84: ...e see Table A 6 System Options Framed The unit conforms to G 704 framing format Unframed G 704 framing is disabled Line Coding Possible Settings AMI HDB3 Default Setting HDB3 Specifies the line coding...

Страница 85: ...Timeslot 16 Data Time slot 16 is used for data the card is in data mode Primary Clock Source Possible Settings Internal G 703 Default Setting Internal Determines the primary clock source for the unit...

Страница 86: ...ting 1 Controls the source of the configuration options 1 8 The configuration of the selected port is copied To Port y Possible Settings 1 2 3 4 5 6 7 8 All Default Setting 2 Controls the target of th...

Страница 87: ...this menu selection sequence Main Menu Configuration Current Configuration System Options main config system Slot 4 Model 8799 SYSTEM OPTIONS DSL Mode STU C Test Timeout Enable Test Duration min 10 G...

Страница 88: ...ter a test is accidentally executed Enable Loopback and pattern tests end when test duration is reached Disable Tests run until manually terminated from the DSLTests screen or remotely Refer to Runnin...

Страница 89: ...om it is a requirement that the product comply with the OFTel PSD mask for the loop length requested short medium or long Support for this requirement is provided by enabling Spectrum Management and p...

Страница 90: ...may be sourced from the G 703 interface which is generating timing or from the internal oscillator on the card providing a Stratum 4 reference Typically the primary clock source is a G 703 port which...

Страница 91: ...to generate timing which is consistent with the last clock reference A switch is made back to the primary clock when it becomes available Holdover mode is meant to be used for short durations while ne...

Страница 92: ...DSL Port 6 DSL Port 7 DSL Port 8 DS1 Bypass DS1 Bypass STU R DS0 or DS1 Cross Connect G 703 Port 1 G 703 Port 2 G 703 Port 3 G 703 Port 4 G 703 Port 5 G 703 Port 6 G 703 Port 7 G 703 Port 8 Stratum 1...

Страница 93: ...ort must be enabled Internal Timing is derived from the internal oscillator which provides a Stratum 4 reference System Secondary Clock Reference Possible Settings STU C G 703 Port 1 8 Internal Defaul...

Страница 94: ...ction sequence Main Menu Configuration Current Configuration Cross Connect Select Set Cross Connect Mode to configure the cross connect mode for each port Assign Time Slots to assign time slots for ea...

Страница 95: ...ign Time Slots screen to be displayed Select Clear_All to change the Mode of all enabled ports to DS0 Cross Connect All DSL port numbers and time slot assignments are cleared For information about the...

Страница 96: ...erfaces DS0 Cross connect Individual time slots of the G 703 or DSL interface may be connected to any time slot of any of the other interfaces configured for DS0 cross connect Unassigned None of the t...

Страница 97: ...he following screen is displayed for a G 703 port main config cross_connect timeslot Slot 18 Model 8799 ASSIGN TIME SLOTS G 703 Port 1 DSOs to Allocate Start TS Assign To D TS01 TS02 TS03 TS04 TS05 TS...

Страница 98: ...imum number of useful DSL time slots depends on the configuration see Table A 2 Payload Rates and DSL Line Rates for G 703 Useful DSL time slots are contiguous and start at Time Slot 1 main config cro...

Страница 99: ...is connected 1 8 The port number is specified DS0s to Allocate Possible Settings 1 31 Default Setting Blank Specifies the number of contiguous time slots to be assigned at this time for the selected...

Страница 100: ...the slot to which this time slot is connected 1 31 The time slot to be assigned Data or Voice Possible Settings d v Default Setting d Determines whether the time slot is dedicated to the transmission...

Страница 101: ...A 13 General SNMP Management Options To access the General SNMP Management Options screen follow this menu selection sequence Main Menu Configuration Current Configuration Management and Communicatio...

Страница 102: ...able A 6 System Options ASCII text field Enter or edit a community name public The community name is set to public Name 1 Access Possible Settings Read Read Write Default Setting Read Write Determines...

Страница 103: ...tting Read Determines the access level for Community Name 2 Name 2 Access appears only when DSL Mode is set to STU R see Table A 6 System Options Read Allows read only access get for Community Name 2...

Страница 104: ...config management security Slot 4 Model 8799 SNMP NMS SECURITY OPTIONS NMS IP Validation Enable NMS 1 IP Address 135 014 040 001 Clear Access Type Read Write NMS 2 IP Address 135 014 003 027 Clear Ac...

Страница 105: ...5 Clear Default Setting 000 000 000 000 Specifies the Internet Protocol address used to identify each SNMP manager 001 000 000 000 223 255 255 255 Enter an address for each SNMP manager The range for...

Страница 106: ...uence Main Menu Configuration Current Configuration Management and Communication SNMP Traps main config management trap Slot 4 Model 8799 SNMP TRAPS OPTIONS SNMP Traps Enable General Traps Both Enterp...

Страница 107: ...ble Settings Enable Disable Default Setting Disable Determines if SNMP traps are generated for enterprise specific events Enable SNMP traps are generated for enterpriseSpecific events NOTE Refer to En...

Страница 108: ...inkDown and interface related enterpriseSpecific traps are generated for the DSL interface and or G 703 interface DTE Network SNMP trap messages are generated for the DSL interface G 703 SNMP trap mes...

Страница 109: ...Channel Disable Disables the Inband Management Channel Inband Management Type Possible Setting PPP Frame Relay Default Setting PPP Specifies the type of data the Inband Management Channel will accept...

Страница 110: ...ce LMI the Inband Management Channel will use when Inband Management Type is set to Frame Relay Annex A The LMI supported is specified by Q933 Annex A Annex D The LMI supported is specified by ANSI T1...

Страница 111: ...ternal for Management Port Type and the slot number of the 8799 line card to be used for Inband Management in the Management Port Card Slot field Then Enter yes to reset the port and save your changes...

Страница 112: ...Slot 18 Model 8799 CROSS CONNECT MODE Source Destination G 703 MODE DSL 1 DS0 Cross connect Unassigned 2 DS0 Cross connect Unassigned 3 DS0 Cross connect Unassigned 4 DS0 Cross connect Unassigned 5 D...

Страница 113: ...nt Configuration Cross Connect Assign Time Slots The following screen is displayed main config cross_connect timeslot Slot 18 Model 8799 ASSIGN TIME SLOTS G 703 Port 1 DSOs to Allocate Start TS Assign...

Страница 114: ...ne Card download the configuration file to an external TFTP server on your network If an SNMP trap manager is available generate a trap and verify that the trap was received by the trap manager If Ope...

Страница 115: ...tionFailure linkUp and linkDown warmStart authenticationFailure SNMP Trap Description Possible Cause warmStart The card has reinitialized itself The trap is sent after the card resets and stabilizes T...

Страница 116: ...the slot number times 1000 plus 2 Backplane HDLC Interface 3 10 DSL E1 Interface Port 1 Port 8 15 22 G 703 Port 1 Port 8 39 46 EOC management link DSL1 DSL8 ifAdminStatus RFC 2863 This object specifi...

Страница 117: ...e of one or more of the card s hardware components enterprisePrimary ClockFailClear 101 The Clock Fail condition has cleared enterpriseSelfTestFail 2 A hardware failure of the card is detected during...

Страница 118: ...ops the test in progress testLoopLLB Initiates a Local Loopback testLoopRLB Initiates a Repeater Loopback testSendMon511 Initiates a Send and Monitor 511 test testSendLLBUp Initiates an LLB Up message...

Страница 119: ...Severely Errored Seconds threshold has been reached exceeded for the HDSL2 SHDSL segment endpoint identified hdsl2ShdslEndpointCurr15Min SES hdsl2ShdslEndpointThresh SES hdsl2ShdslPerfCRC anomaliesTh...

Страница 120: ...Fault 12 The bit setting for dcContinuityFault in the hdslShdslEndpointCurr Status object for this endpoint has changed hdsl2ShdslEndpointCurrStatus hdsl2ShdslconfigInitFailure 13 The bit setting for...

Страница 121: ...e System Clock screen configure the system clock On the Cross Connect Mode screen Define all DS1 Bypass ports Define all DS1 Cross Connect ports Define all DS0 Cross Connect ports On the Assign Time S...

Страница 122: ...SL interface or another G 703 port through cross connect circuitry Ports can be switched through software DS0 Cross Connect mode Any time slot of any G 703 interface can be connected to any time slot...

Страница 123: ...Channel Signaling CCS that are in DS0 Cross Connect mode you must explicitly configure the cross connections for Time Slot 16 and related time slots G 703 DSL Port 1 Voice Data Port 1 G 703 DSL Port 2...

Страница 124: ...2 have been changed to DS1 Bypass and Ports 4 8 have been changed to DS0 Cross connect Unassigned appears next to Port 3 because time slots associated with the cross connection have not yet been assi...

Страница 125: ...n time slots to the DSL interfaces using the Assign Time Slots screen To access this screen either select Assign_DS0s on the Cross Connect Mode screen or follow this menu selection sequence Main Menu...

Страница 126: ...device as shown in Figure C 1 Model 8799 Star Chaining main config cross_connect timeslot Slot 18 Model 8799 ASSIGN TIME SLOTS G 703 Port 1 DSOs to Allocate Start TS Assign To D TS01 TS02 TS03 TS04 T...

Страница 127: ...PO RT S 4 8 TDM SHDSL 8799 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8 TDM SDSL 8779 SY ST EM OK Al rm Te st 1 2 3 5 6 7 PO RT S 4 8779 8799 8779 8799 8 Users Data x 64 Kbps 512 Kbps 512 Kbps 192...

Страница 128: ...hen a G 703 port is configured for Channel Associated Signaling CAS or Common Channel Signaling CCS Time Slot 16 is used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G...

Страница 129: ...sed for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS0...

Страница 130: ...used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS...

Страница 131: ...used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS...

Страница 132: ...used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS...

Страница 133: ...used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS...

Страница 134: ...used for signaling and is unavailable for cross connection TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 D D D D D D D TS08 TS...

Страница 135: ...hen a G 703 port is configured for CCS in a DS0 Cross Connect the user must cross connect Time Slot 16 and any associated time slots TS01 Port Type D DSL G G 703 I IBMC Port Number 1 8 Time Slot 1 31...

Страница 136: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 137: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 138: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 139: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 140: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 141: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 142: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 143: ...01 Port Type D DSL G G 703 Port Number 1 8 Time Slot 1 31 d Data or v Voice TS01 TS02 TS03 TS04 TS05 TS06 TS07 G G G G G G G TS08 TS09 TS10 TS11 TS12 TS13 TS14 G G G G G G G TS15 TS16 TS17 TS18 TS19 T...

Страница 144: ...C Cross Connecting Ports C 24 April 2003 8799 A2 GB20 10...

Страница 145: ...the Hotwire 8799 TDM SHDSL Line Card provide the 4 wire G 703 interface from each DSL port to the DTE The following table lists the pin assignments for each of these interfaces Table D 1 Front Panel D...

Страница 146: ...14 Data Out Tip 38 Data In Tip 13 Data In Ring Port 6 42 Data Out Ring 17 Data Out Tip 41 Data In Tip 16 Data In Ring Port 7 45 Data Out Ring 20 Data Out Tip 44 Data In Tip 19 Data In Ring Port 8 48 D...

Страница 147: ...The Hotwire 8799 TDM SHDSL Line Card contains a DC to DC converter that requires 48V power input The 48V power is distributed through the Hotwire DSLAM backplane Maximum Power Dissipation 19 watts Re...

Страница 148: ...E Technical Specifications E 2 April 2003 8799 A2 GB20 10...

Страница 149: ...amples A 17 system clock references A 19 Community Name 1 and 2 A 28 Access A 28 for SNMP 6 3 Configuration Configuration Loader 3 6 Copy Port Options A 12 Cross Connect A 20 Current and Default Facto...

Страница 150: ...DSLAM ending a session 2 9 management serial port 1 2 2 1 DTE connector pin assignments D 1 Loopback 5 5 E EIA 530 Payload Rate A 3 Embedded Operations Channel EOC 1 2 ending an ATI session 2 9 tests...

Страница 151: ...he ATI 3 12 MCP FFS 3 6 Memory Failed self test results message 4 7 menu hierarchy 2 4 messages alarm and device 6 1 and troubleshooting 6 1 error 6 4 health and status 4 3 self test results 4 7 test...

Страница 152: ...iting access 6 3 NMS Security Options 6 3 A 30 system entries 3 2 Traps B 1 enabling disabling A 33 Options A 32 support 1 6 Source A 22 specifications E 1 startup 2 1 Startup Margin A 3 status Port G...

Страница 153: ...g configuring SNMP traps 6 2 Current DSL Performance Statistics 4 15 DSL performance statistics 4 11 error statistics 4 9 G 703 Performance Statistics 4 13 Inband Management Statistics 4 17 table 6 6...

Страница 154: ...Index IN 6 April 2003 8799 A2 GB20 10...

Отзывы: