A. Configuration Options
A-38
April 2003
8799-A2-GB20-10
The Cross Connect Mode screen appears.
5. Configure the G.703 port to be used for Inband Management to DS0
Cross-connect and save your changes.
6. Use the Inband Management Channel screen on the 8799 line card to
configure Inband Management. From the 8799 line card, follow this menu
selection sequence:
Main Menu
→
Configuration
→
Current Configuration
→
Management and Communication
→
Inband Management Channel
main/config/xConnect_mode
Slot: 18 Model: 8799
CROSS CONNECT MODE
Source Destination
G.703 MODE DSL
1 DS0 Cross-connect Unassigned
2 DS0 Cross-connect Unassigned
3 DS0 Cross-connect Unassigned
4 DS0 Cross-connect Unassigned
5 DS0 Cross-connect Unassigned
6 DS0 Cross-connect Unassigned
7 DS0 Cross-connect Unassigned
8 DS0 Cross-connect Unassigned
Assign_DS0s
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save Clear_All
main/config/management/inband
Slot: 4 Model: 8799
INBAND MANAGEMENT CHANNEL
Inband Management Select: Enable
Inband Management Type: PPP
Inband Management Port: 1
Inband Management Time Slot: 1
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save