C. Cross-Connecting Ports
C-2
April 2003
8799-A2-GB20-10
Determining the Configuration
The Hotwire cross-connect system allows you to connect the G.703 ports to the
DSL ports in a variety of ways:
DS1 Bypass mode
– The entire G.703 interface is connected to the DSL
interface.
DS1 Cross-Connect mode
– The entire G.703 interface is connected to the
DSL interface or another G.703 port through cross-connect circuitry. Ports can
be switched through software.
DS0 Cross-Connect mode
:
— Any time slot of any G.703 interface can be connected to any time slot of
any DSL interface.
— Any time slot of any DSL interface can be connected to any time slot of
any other DSL interface.
— Any time slot of any G.703 interface can be connected to any time slot of
any other G.703 interface. See the example below.
Time slots can be individually allocated for voice or data.
G.703
Internal Ports
8799
Line Cards
02-17123