4. Monitoring the Card
4-14
April 2003
8799-A2-GB20-10
Status:
Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
—
Y:
Remote alarm indication signal received at the G.703 interface
—
L:
Loss of signal detected at the G.703 interface
—
E:
Excessive error rate threshold exceeded
—
F:
Frame synchronization bit error detected
—
V:
Line code violation detected
—
NONE:
No significant events have occurred
Fields on this screen include:
This Field . . .
Contains . . .
Current Interval Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds
(15 minutes). This counter resets every 15 minutes.
Error Events Counter
A running total of CRC errors. Range 0–65535. This counter
resets when the near-end data is cleared.
Current Int
Performance data for the current 15-minute interval.
When 0, the port is either disabled or configured for
Unframed operation.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours).
Worst Interval
The number of the interval with the worst (highest) performance
data for both the near- and far-end statistics. If two or more
intervals are equal, the oldest interval is displayed.
Tot
A running total of the performance statistics.
Содержание Hotwire 8799
Страница 24: ...2 Using the Asynchronous Terminal Interface 2 10 April 2003 8799 A2 GB20 10...
Страница 68: ...5 Testing 5 10 April 2003 8799 A2 GB20 10...
Страница 144: ...C Cross Connecting Ports C 24 April 2003 8799 A2 GB20 10...
Страница 148: ...E Technical Specifications E 2 April 2003 8799 A2 GB20 10...
Страница 154: ...Index IN 6 April 2003 8799 A2 GB20 10...