No. SX-DSV03224-63-
R6.0
Motion Control Business Unit, Panasonic Corporation
8-3-2 Wiring to connector X4
[1] The customer is required to prepare the 12 to 24 VDC control signal power supply for external control to be
connected to SI-COM. Insulation is needed against the primary side power supply (power supply of the
motor brake).
Do not connect to the same power supply.
[2] Install peripheral devices close to the servo driver as much as possible so that wiring length is minimized
(within 3 m).
[3] Keep the cables away from the wiring of the power lines (L1, L2, L3, L1C, L2C, U, V, W,
) as much
as possible (at least 30 cm). Do not put them in the same duct or bind them together.
Control input
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
4.7 kΩ
1 kΩ
Servo Driver
DC 12~24 V
SI-COM
SI1
SI2
SI3
SI5
SI6
SI7
SI4
6
X4
SI8
4.7 kΩ
1 kΩ
5
7
9
8
11
12
10
13
The functions of SI 1 to SI 8 are assigned with parameters.
For details, refer to "Technical
Reference
-Functional Specification-".