No.SX-DSV03224 Appendix1
MODEL
Category
Pr.
Parameter
Default
value
Category
Pr.
Parameter
Default
value
Category
Pr.
Parameter
Default
value
Category
Pr.
Parameter
Default
value
Category
Pr.
Parameter
Default
value
5
0 No use
-
5
31 USB axis address
1
5
62
No use
-
1 No use
-
32 No use
-
63
No use
-
2 No use
-
33
Pulse regenerative output limit
setup
0
64
No use
-
3
Denominator of pulse output
division
0
34 For Manufacturer use
4
65
No use
-
4
Over-travel inhibit input
setup
1
35 No use
-
66
*1
Deterioration diagnosis
convergence judgment time
0
5
Sequence at over-travel
inhibit
0
36 For Manufacturer use
0
67
Deterioration diagnosis inertia
ratio upper limit
0
6 Sequence at Servo-off
0
37
No use
-
68
Deterioration diagnosis inertia
ratio lower limit
0
7 Sequence at main power off
0
38
No use
-
69
*1
Deterioration diagnosis unbalanced
load upper limit
0
8
LV trip selection at main power
off
1
39
No use
-
70
*1
Deterioration diagnosis unbalanced
load lower limit
0
9
Detection time of main power off
70
40
No use
-
71
*1
Deterioration diagnosis dynamic
friction upper limit
0
10 Sequence at alarm
0
41
No use
-
72
*1
Deterioration diagnosis dynamic
friction lower limit
0
11
Torque setup for emergency stop
0
42
No use
-
73
*1
Deterioration diagnosis viscous friction
upper limit
0
12 Over-load level setup
0
43
No use
-
74
*1
Deterioration diagnosis viscous friction
lower limit
0
13 Over-speed level setup
0
44
No use
-
75
Deterioration diagnosis velocity
setting
0
14
*1
Motor working range setup
1.0
45
*1
Quadrant glitch positive-direction
compensation value
0
76
Deterioration diagnosis torque
average time
0
15
Control input signal reading setup
0
46
*1
Quadrant glitch negative-
direction compensation value
0
77
*1
Deterioration diagnosis torque
upper limit
0
16
No use
-
47
Quadrant glitch compensation
delay time
0
78
*1
Deterioration diagnosis torque
lower limit
0
17
No use
-
48
*1
Quadrant glitch compensation
filter setting L
0.00
18
No use
-
49
*1
Quadrant glitch compensation
filter setting H
0
19
No use
-
50 For Manufacturer use
0
20 Position setup unit select
0
51 For Manufacturer use
0
21 Selection of torque limit
1
52 For Manufacturer use
0
22
*2
2nd torque limit
500
53 For Manufacturer use
0
23
Torque limit switching setup 1
0
54 For Manufacturer use
0
24
Torque limit switching setup 2
0
55 For Manufacturer use
0
25
*2
Positive direction torque limit
500
56
Slow stop deceleration time
setting
0
26
*2
Negative direction torque
limit
500
57
Slow stop S-shape acceleration
and deceleration setting
0
27 No use
-
58
No use
-
28 No use
-
59
No use
-
29 For Manufacturer use
2
60
No use
-
30 No use
-
61
No use
-
■Default value of the parameters (6/11)
PARAMETER
MINAS-A6N (NL/NM) series common
*1 When checking directly value of parameter-file with a text data etc., it does not show the decimal point.
Ex) Pr6.24 Load change compensation filter
・・・
Value of Panaterm
:
0.53 / Value of parameter-file
:
53
* Parameter names in the table correspond to the DD motor (rotary type). For parameter names and setting values corresponding to linear motors, refer to the technical document.