No. SX-DSV03224-34-
R6.0
Motion Control Business Unit, Panasonic Corporation
Size C, D 100 V / 200 V
Pin No.
Symbol
Name
Description
XA
5
L1
Main power input
terminal
100 V
Single phase
100-120 V
+ 10 %
50/60 Hz
- 15 %
Use L1 and L3 terminal for single phase input
4
L2
200 V
Single or 3 phase
200 – 240 V
+ 10 %
50/60 Hz
- 15 %
3
L3
Use L1 and L3 terminal for single phase input
2
L1C
Control power
input terminal
100 V
Single phase
100-120 V
+ 10 %
50/60 Hz
- 15 %
1
L2C
200 V
Single phase
200 – 240 V
+ 10 %
50/60 Hz
- 15 %
XC
4
N
-
Do not connect anything to this connector.
3
2
P
1
XB
6
P
Regenerative
resistor connecting
terminal
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between RB
and B and connect an external regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Reference - Functional Specification ".
5
RB
4
B
3
U
Motor output
terminal
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
When using Voice coil motor, connect the following.
U: U phase W: W phase
Do not connect anything to V terminal.
For details, refer to "Technical Reference - Function Specification-"
2
V
1
W
Earth
Earth terminal for grounding
*Tighten the Earth screw with a torque of M4: 1.0 to 1.2 N · m.