No. SX-DSV03224-42-
R6.0
Motion Control Business Unit, Panasonic Corporation
7-3 RTEX connectors X2A X2B
For connection, use RJ45 connector
[X2A] RX connector
Name
Symbol
pin no.
Description
Unused
-
1
Connect to pin 1 on TX connector of sending side node.
Unused
-
2
Connect to pin 2 on TX connector of sending side node.
Network input +
RX+
3
Connect to pin 3 on TX connector of sending side node.
Unused
-
4
Connect to pin 4 on TX connector of sending side node.
Unused
-
5
Connect to pin 5 on TX connector of sending side node.
Network input -
RX-
6
Connect to pin 6 on TX connector of sending side node.
Unused
-
7
Connect to pin 7 on TX connector of sending side node.
Unused
-
8
Connect to pin 8 on TX connector of sending side node.
Frame ground
FG
Shell
Connect to shield of cable.
[X2B] TX connector
Name
Symbol
pin no.
Description
Unused
-
1
Connect to pin 1 on RX connector of receiving side node.
Unused
-
2
Connect to pin 2 on RX connector of receiving side node.
Network
TX+
3
Connect to pin 3 on RX connector of receiving side node.
Unused
-
4
Connect to pin 4 on RX connector of receiving side node.
Unused
-
5
Connect to pin 5 on RX connector of receiving side node.
Network output -
TX-
6
Connect to pin 6 on RX connector of receiving side node.
Unused
-
7
Connect to pin 7 on RX connector of receiving side node.
Unused
-
8
Connect to pin 8 on RX connector of receiving side node.
Frame ground
FG
Shell
Connect to shield of cable.
* Be sure to use shielded twisted pair (STP) compatible with 5e of TIA/EIA-568 or higher category
7-4 Safety function connector X3
This connection is for functional safety.
This connector is compatible with multifunction type only.
Name
Symbol
pin No
Description
Input/output
signal interface
Reserved
−
1
・
Do not connect anything to this connector.
-
−
2
-
Safety input 1
SF1-
3
2 channel inputs with independent circuit
to cut off the drive signal to the power module
in the servo driver.
i-1
SF1+
4
Safety input 2
SF2-
5
SF2+
6
EDM output
EDM-
7
・
It is monitor output for monitoring malfunctions of
the safety function.
o-1
EDM+
8
Frame ground
FG
shell
・
Internally connected to the earth terminal.
-
Note 1)
The signal ground GND is connected with the control circuit ground connected with the connector X3 .
Note 2) “Safety Integrity Level 3(SIL3)”, “Performance level e (PL e)” and “DCavg Medium” are accomplished with
diagnosis of “EDM output” (maximum interval time is 3 months). Without diagnosis of “EDM output”, the safety Integrity Level is
2 (SIL2), Performance level d (PL d) and “DCavg Low”.