No. SX-DSV03224-51-
R6.0
Motion Control Business Unit, Panasonic Corporation
Size C, D 100 V / 200 V
L1
L2
L3
L
ON
MC
OFF
ALM
L1C
L2C
P
MC
U
V
W
ALM+
ALM-
ALM
MCCB
B
+
-
N
XA
XC
X4
XB
RB
P
Short wire
*Please remove it when using
external regenerative resistor
Built- in Thermostat of an external regenerative resistor
( The wire color of optional accessories is light yellow)
Coil surge absorber
Main power
supply
Control power
supply
Motor output
*
When using with single
phase power supply, be sure
to connect between L1 and
L3 terminals.
Power supply
(3-phase)
Red
White
Black
Green or
Green/yellow
Isolated power supply
DC12
~
24 V
(
±
5 %)
external
regenerative resistor
N
oi
se
f
ilt
er
Thermostat
( See above)
M
When using the amplifier with VCM,
connect the U and W terminals
■
Connection of regenerative resistor
Size
Short wire
(accessory)
Internal
regenerative
resistor
Connection of connector XB
In case of using the external
regenerative resistor
In case of not using the external
regenerative resistor
C
D
Installed
Installed
Between RB and B:
Disconnect the short cable
Between P and B:
Connect the external
regenerative resistor
Between RB and B:
Connect the shorting cable
* The circuit connected to terminal X1 – X7 are secondary circuits. (See [5. Appearance and name of each part ])
Insulation is needed against the primary side power supply (power supply of the motor brake).
Please do not connect them with the same power supply.
* For details, refer to 7-1 Power connector XA, XB, XC, XD and terminal block.