No. SX-DSV03224-59-
R6.0
Motion Control Business Unit, Panasonic Corporation
Size F 400 V
L1
L2
L3
L
ON
MC
OFF
ALM
24V
0V
P
MC
U
V
W
ALM+
ALM-
ALM
MCCB
+
-
RB
Terminal
X4
N
B
Built- in Thermostat of an external regenerative resistor
( The wire color of optional accessories is light yellow)
Coil surge absorber
Main power
supply
Control power
supply
Power supply
(3-phase)
N
oi
se
f
ilt
er
Short wire
*Please remove it when using
external regenerative resistor
external
regenerative resistor
Motor output
Isolated power supply
DC12
~
24 V
(
±
5 %)
Green or
Green/yellow
Red
White
Black
Thermostat
( See above)
XD
Isolated power supply
DC24V
+
-
M
When using the amplifier with VCM,
connect the U and W terminals
Connection of a regenerative resistor
Size
Short bar
(accessory)
Built-in
regenerative
resistor
Connection of the Terminal
In case of using the external
regenerative resistor
In case of using the external
regenerative resistor
F
Installed
Installed
Between RB and B:
Disconnect the short bar
Between P and B:
Connect the external
regenerative resistor
Between RB and B:
Connect the short bar
* The circuit connected to terminal X1 – X7 are secondary circuits. (See [5. Appearance and name of each part ])
Insulation is needed against the primary side power supply (power supply of the motor brake).
Please do not connect them with the same power supply.
* The standard of the ability of the built-in dynamic brake resistor is up
to continuousness three times in the stop from the allowance and maximum inertia and the rated speed.
Resistor is damaged and the dynamic brake might not work when using it under more critical operating condition.
* For details, refer to 7-1 Power connector XA, XB, XC, XD, and terminal block