No. SX-DSV03224-82-
R6.0
Motion Control Business Unit, Panasonic Corporation
- Notes
· Select a circuit breaker (MCCB) and a noise filter with capacity appropriate for power supply capacity
(considering load conditions).
· Terminal block and ground terminal, Use copper conductor wires with a temperature rating of 75 ° C or higher for wiring.
The protective earth terminal is from size A to size E is M4, size F to size G is M5, size H is M6. If the tightening torque
of the screw exceeds the maximum value (refer to the terminal block explanation page), the terminal block may be damaged.
· The wire diameter of the ground wire is at least 2.0 mm
2
(AWG 14) at 50 W to 2.5 kW output, 3.5 mm
2
(AWG 12) or more
at 3.0 kW to 5.0 kW output, 7.0 kW at 8.0 mm
2
(AWG 8 ) Or more, please use 22 mm
2
(AWG 4) or more for output 15.0
kW and 38 mm
2
(AWG 2) or more for 22.0 kW output.
· Use the supplied dedicated connector from size A to E.
· Tighten the screw of the connecting connector (X4) to the host controller at a tightening torque of 0.3 to 0.35 N · m.
If it exceeds 0.35 N · m, the driver side connector may be damaged.
Optional part number
Part number of
manufacturer
Manufacturer
Absorber
DV0P1450
R
A
V-781BXZ-4
Okaya Electric Industries
DV0P4190
R
A
V-781BWZ-4
LT-C34G801WS
Soshin Electric
Ferrite core
DV0P1460
ZCAT3035-1330
TDK
-
RJ8095
Konno Kogyousho
-
T400-61D
MICROMETALS
Noise filter
DV0P4170
SUP-EK5-ER-6
Okaya Electric
Industries
DV0P4220
3SUP-HU30-ER-6
DV0P3410
3SUP-HL50-ER-6B
DV0PM20042
3SUP-HU10-ER-6
DV0PM20043
3SUP-HU50-ER-6
-
HF3080C-SZA
Soshin Electric
-
HF3100C-SZA
-
HF3040C-SZC
-
FN3258-16-44
Schaffner EMC
-
FN3258-30-33