PB
Use the
<-DAY>
and
<+DAY>
soft keys to preset the
interval day to initiate an automatic equalization cycle.
The
EQ INTERVAL
displays the number of days in the
interval between cycles and
COUNT
displays how many
days of the interval have passed. To view the
MAIN EQ
screens, press the
<EXIT>
soft key.
Press the first soft key twice to return to the
MAIN
Menu.
Press the
< >
soft key until the
g
is in front of
Misc
.
Press the
<GO>
soft key to view the
Misc
screen.
NOTE:
•
Auto Mode
initiates when a preset interval day (1-250 days) is reached.
• The default equalize interval (EQ INTERVAL) setting is 000 day leaving the auto eq disabled.
• EQ-MPPT display indicates the FLEXmax 80 is trying to reach the target equalize set point.
• The equalize time
EQ 0:00
in Hours:Minutes displays after the equalize set point is reached.
• An incomplete equalization cycle continues into the next day unless the FLEXmax 80 is powered off
or manually stopped. The remaining
EQ
time can be viewed in the Stats Menu.
• The
COUNT
value will be cleared to 000 when an
EQ
is started, manually stopped, or FLEXmax 80 has
been powered off.
• After recharging, an
EQ DONE
message displays and a
Float
cycle begins. EQ DONE is displayed until
(1) any soft key is pressed or (2) a new day occurs for systems using an OutBack MATE.
COUNT
EQ INTERVAL
00
000
EXIT -DAY +DAY
BATTERY EQUALIZE
Volts
15.0
EXIT NEXT -EQV +EQV
AUTO MODE
Charger Aux
Light
Eq
g
Misc Advanced
Logging Stats
EXIT
f
g
GO
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...