PB
8. Accessing the MAIN Menu
The
MAIN
Menu allows the user to adjust and calibrate the FLEXmax 80 for maximum performance.
From the
STATUS
screen, press the first soft key on the left to open the
MAIN
Menu
screen.
Press the
<GO>
soft key after aligning the arrow in
front of the selected menu choice.
Pressing the
<EXIT>
soft key in the
MAIN
Menu
returns to the
STATUS
screen.
From the
MAIN
Menu, a user can choose among the following FLEXmax 80 functions by aligning the
arrow:
•
Charger—CHARGER SETUP
- Adjusts the Current Limit, Absorb, and Float recharging voltage set points
•
Aux—AUX OUTPUT CONTROL
- Secondary control circuit for a vent fan, error alarm, and other system-related additions
•
Light—BACKLIGHT CONTROL
- Adjusts the backlighting of LCD screen and soft key buttons
•
EQ—BATTERY EQUALIZE
- Activates battery equalization recharging (manually or automatically)
•
Misc—MISCELLANEOUS
- Additional settings and service information
•
Advanced —ADVANCE MENU
- Optimizing/fine-tuning the FLEXmax 80 (these are advanced Menus that should be left alone
until the user has a good working knowledge of the FLEXmax 80 and its operations)
•
Logging—DATA LOGGING
- Displays recorded power production information
•
STATS—Statistics
- Displays recorded peak system information and cumulative kilowatt hours and amp hours
g
Charger Aux Light
EQ Misc Advanced
Logging Stats
EXIT
f
g
GO
Press
or
to move the " “ to
the left of the desired screen. The arrow
allows access to any screen to its right.
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...