8
PB
In the
Low Batt Disconnect
screen, press the
<VOLT>
soft
key to adjust the battery voltage disconnects
set point.
Press either the
< - >
or the
< + >
soft key to adjust the
disconnect voltage. Press the
<ReCon>
soft key to open
the
RE-CONNECT VOLTS
screen.
Press either the
< - >
or the
< + >
soft key to adjust the
RE-CONNECT VOLTS
value. The AUX Output activates
when the voltage goes above this setting after the timer
has counted back to zero. Press the
<BACK>
soft key
to return to the
Low Batt Disconnect
screen. Press the
<DisV>
soft key to return to the
Disconnect Volts
screen.
AUX MODE
Low Batt Disconnect
EXIT TIME VOLT
DISCONNECT VOLTS
< 13.6
BACK - + ReCon
RE-CONNECT VOLTS
> 14.4
BACK - + DisV