PB
VENT FAN
Press the
<MODE>
soft key to manually activate
or deactivate (
On
or
Off
) the
Vent Fan
; if set to
Auto
,
the
Vent Fan
will turn on when a user-determined
voltage is met. Press the
<SET>
soft key to view
the
Vent Fan
screen. To view other screens, con-
tinue to press the
<NEXT>
soft key.
The
Vent Fan
helps remove hydrogen from the bat-
tery box. The ventilation fan referred to here is not
the same as the FLEXmax 80 cooling fan. Press the
<VOLT>
soft key to determine the battery voltage
that will activate the AUX MODE and start the fan.
Adjust the voltage level using the
< - >
and
< + >
soft keys. Press the
<BACK>
soft key to return to
the
Vent Fan
screen.
AUX MODE
Vent Fan
Output: Off Off
EXIT NEXT SET MODE
AUX MODE
Vent Fan
EXIT VOLT
VENT FAN VOLTS
> 14.4
BACK - +
On
Off
Auto
. Programming the AUX MODES