PB
. MISC—Miscellaneous
The MISCELLANEOUS screens display extra settings and technical information, some of which is
useful for OutBack Power Systems Technical Services.
The Grid Tie (GT) value is sent
from G-series inverter through the
MATE and HUB for Grid Tie control
communications. GT means THE
FLEXmax 80 is in grid tie mode
and communicating with the GT
Series Inverter.
Each MPPT operation is
a state. This number
is useful for OutBack
troubleshooting.
This is the duty cycle of
the converter. At 50%, the
PV terminals would be
twice the battery voltage.
The Bulk/Absorb charge
timer counts up to the
Absorb time limit.
Press
NEXT
to
Continue to the Force
Bulk/Float Screen.
RSTRT forces the FLEXmax 80 to
restart or wake-up from 5-minute
(default) long Snoozing mode.
Restart and wakeup are mainly
service features.
GT State PWM% ChgT
255 07
50.0 005
EXIT NEXT
RSTRT