PB
Press the
<NEXT>
soft key ro view the
AUX Float
screen.
The
AUX MODE
is active when the FLEXmax 80 is in
Float
and producing power. Press the
<NEXT>
soft
key to advance to the
Diversion
screen.
When external DC sources (wind, hydro) are directly
connected to a battery bank, any excess power
should be sent to a diversion load, such as a heat-
ing element, via a mechanical or solid state relay.
In
Diversion
, which features
Relay
and
Solid State
screens, the user programs set points—from -5.0
volts to 5.0 volts relative to the Absorb, Float and EQ
voltages—to activate the
AUX MODE
. With wind or
hydro generator applications, keep the FLEXmax 80’s
diversion voltage slightly above its Absorb and Float
voltages for efficient functioning.
This is primarily an off-grid function. Pressing the
<MODE>
soft key displays
Auto
and
On
modes in
addition to
Off.
Pressing the
<SET>
soft key displays
the
Diversion: Relay
TIME
and
VOLT
screen.
AUX MODE
Night Light
Output: Off Auto
EXIT NEXT SET MODE
FLOAT
AUX MODE
Float
Output: Off Off
EXIT NEXT SET MODE
On
Off
Auto
RELAY
AUX MODE
Diversion: Relay
Output: Off Off
EXIT NEXT SET MODE
On
Off
Auto
AUX MODE
Night Light
EXIT HYST TIME VOLT
Press the
<EXIT>
soft key to return to the
Night Light
AUX
mode.
g
g
g
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...