8
PB
8. Advanced Menu (Micro-Hydro and Fuel Cell Applications)
Mpp Range Limit % (Auto Track Mode only)
The FLEXmax 80 searches for the MPP voltage by tracking the input voltage up to one half (default) of
the Voc, which is based on values appropriate for a solar array. Micro-hydro and fuel cell systems can
require a broader range, normally on the lower end. Adjusting the lower limit, expressed as
1/2
on the
display screen, for
FULL
allows the FLEXmax 80 to track the input voltage close to the battery voltage
instead of 1/2 (or 50%) of the Voc.
This adjustment only affects the initial tracking at the beginning of the day and any subsequent trackings
caused by Auto-Restart or any forced restart of the FLEXmax 80.
To adjust the Lower Mpp Range Limit:
From the
MAIN
Menu, with the arrow in front of
Advanced,
press the
<GO>
soft key.
In the ADVANCED MENU screen, press the
<NEXT>
soft
key until the
Mpp Range Limit % Voc
screen appears. Press
the
<1/2>
soft key until
FULL
appears. When finished,
press the
<NEXT>
soft key until the
MPPT Mode
screen
appears.
To pick between
Auto Track
or
U-Pick % MPPT
Mode and
determine the FLEXmax 80’s operating Voc percentage,
press the
<MODE>
soft key to interchange between the
two modes. Re-entering the password might be required.
After choosing a mode, press the
<NEXT>
soft key in
the
ADVANCED MENU
to view the
Park Mpp
screen (only
applicable for
U-Pick
mode).
Press the
<-VOC>
or
<+VOC>
soft key to select one of
the percentage values;
U-Pick
always uses the
Park Mpp
value.
Charger Aux Light
Eq Misc
g
Advanced
Logging Stats
EXIT
f g
GO
ADVANCED MENU
Mpp Range Limit %Voc
Min Max
EXIT NEXT 1/2 90%
ADVANCED MENU
MPPT Mode
Auto Track
EXIT NEXT nonGT MODE
ADVANCED MENU
Park Mpp
Watts 0000 77 % VOC
EXIT NEXT –% +%
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...