PB
Hold Time Sec
01.1
BACK - +
AUX MODE
PV Trigger
Output: On On
EXIT NEXT SET MODE
Press the
< - >
or
< + >
soft key to adjust the Hold
Time, then press the
<BACK>
soft key to return to the
PV Trigger
screen. In this example, the
AUX MODE
will
remain active for 1.1 seconds after the PV voltage is
below the
PV Trigger
voltage before deactivating the
PV
Trigger
and reconnecting to the array.
Press the
<EXIT>
soft key to return to the initial
PV Trigger screen
Press the
<NEXT>
soft key to view the
ERROR OUTPUT
screen.