8. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version FLEXmax 80 has a few default settings that differ from the Standard version
default settings. However, there are no differences in performance and efficiency between the two
versions. The Standard and Australian version can be identified as follows:
Standard Version
Australian Version
Below are a few default setting differences between the Standard and Australian version.
Settings
Standard
Australian
Charger
Absorb
Float
Absorb
Float
12V
14.4V
13.6V
14.4V
13.8V
24V
28.8V
27.2V
28.8V
27.6V
36V
43.2V
40.8V
43.2V
41.4V
48V
57.6V
54.4V
57.6V
55.2V
60V
72.0V
68.0V
72.0V
69.0V
Equalize
Equalize Volts
Equalize Volts
12V
14.4
14.7
24V
28.8
29.4
36V
43.2
44.1
48V
57.6
58.8
60V
72.0
73.5
Equalize Time
01 Hours
03 Hours
OutBack
12V
Power
Systems
FLEXmax 80
OutBack
12V
Power
Systems
FLEXmax 80-AU