. Micro-Hydro and Fuel Cell Applications
The FLEXmax 80 is designed to work with solar arrays. Although it will work with micro-hydro turbines
and fuel cell, OutBack Power Systems can only offer limited technical support for these applications
because there is too much variance in micro-hydro and fuel cell generator specifications. When
used for micro-hydro or fuel cell applications, the FLEXmax 80 warranty will be honored only if the
manufacturer and turbine model have been approved by OutBack Power Systems. Please check with
one of the following manufacturers or OutBack Power Systems before employing the FLEXmax 80 with
these applications:
• Harris Hydroelectric
(831) 425-7652
www.harrishydro.com
• Alternative Power & Machine
(541) 476-8916
www.apmhydro.com
• Energy System & Design
(506) 433-3151
www.microhydropower.com
The FLEXmax 80 is not compatible with wind turbine applications
and OutBack cannot
warranty its use in these applications.
MICRO-HYDRO AND FUEL CELL SYSTEMS PERFORMANCE OPTIMIZATION
Micro-hydro and fuel cell systems are different than PV systems, whose VOC output is more subject to
change due to weather and time of day. A PV system normally finds its Maximum Power Point voltage
between 50-90% of its VOC. A micro-hydro or fuel cell system’s MPP voltage can be outside of this
range.
The FLEXmax 80 allows a user to experiment and find more appropriate set points to best capture
the MPP voltage using
U-Pick
mode. Otherwise,
Auto Track
begins tracking the VOC and works its way
down until the optimum percentage of input voltage yields the MPP voltage. If
U-Pick % Voc
is chosen,
the MPP is calculated by whatever value is found in
Park Mpp,
even if it’s not the optimal value for
determining the MPP voltage. For this reason, OutBack normally suggests leaving the system in
Auto
Sweep
mode.
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...