PB
GT State PWM% ChgT
255 07
50.0
005
EXIT NEXT RSTRT
Press the
<NEXT>
soft key to view the
FORCE FLOAT
, or
BULK
screen.
Pressing the
<FLOAT>
or
<BULK>
soft key forces the
FLEXmax 80 to that specific recharging cycle and returns
to the
STATUS
screen. Forcing a
FLOAT
or
BULK
recharge
will end an
EQ
cycle. Press the
<NEXT>
soft key to view
the third
MISCELLANEOUS
screen.
• Force FLOAT = float cycle
• Force BULK = bulk cycle
Press the
<EXIT>
soft key twice to return to the MAIN
MENU.
FORCE
EXIT NEXT FLOAT BULK
PCB Target Btmp CFB
512 14.4v 255 0712
EXIT BACK
This is the assigned number representing
the temperature of the internal components
to control the cooling fan. The lower the
number, the higher the temperature. 25° C is
approximately a value of 525.
Btmp
is a battery temperature sensor reference
value used to compensate the charging voltage.
This is an arbitrary number between 0 and 255
and is not the actual temperature. An ‘X’ next
to this value indicates a Global external RTS is
being used (system with a HUB and MATE).
The output value of the
internal current sensor is
used to calculate output
amps, watts, and track
the Maximum Power
Point of the array.
The target voltage the
controller is trying to reach.
Содержание FLEXMAX 80
Страница 9: ...THE OUTBACK POWER SYSTEMS FLEXmax 80 Maximum Power Point Tracking Charge Controller...
Страница 13: ...12 Figure 2 Single Charge Controller wiring diagram with 24 volt PV array...
Страница 14: ...13 Figure 3 Charge Controller Wiring Diagram with an FX HUB 4 and an RTS...
Страница 15: ...14 Figure 4 Charge Controller with PV array ground fault protection wiring digram...
Страница 37: ...36 Figure 5 Diversion Load and AUX Wiring Set Up Illustrated...