LOW BATTERY DISCONNECT
When the battery voltage falls below the disconnect
volts, the
AUX connected loads only
are disconnected;
the AUX
connected loads only
are connected when
the battery voltage rises above the reconnect volts.
To adjust these set points, press the
<TIME>
and
<VOLT>
soft keys.
Press the
<TIME>
and
<VOLT>
soft keys to adjust the
set points.
Press either the
< - >
or
< + >
soft key to adjust the
delay time. This is the time period the FLEXmax 80
waits before either activating or deactivating the
AUX MODE
when either the disconnect or reconnect
voltages are reached. When the low voltage occurs,
the timer shows the seconds remaining before
disconnecting. When the reconnect voltage is reached,
the timer shows the user-determined time before
connecting. Press the
<BACK>
soft key to return to the
Low Batt Disconnect
screen.
Delay Time Sec
01
Timer
001
BACK - +
AUX MODE
Low Batt Disconnect
Output: On On
EXIT NEXT SET MODE
AUX MODE
Low Batt Disconnect
EXIT TIME VOLT
On
Off
Auto