3.3.7 Meter Display
The Meter Display buttons control what is being viewed on the input module’s LED
Meter and Status Display.
■
Level
Level is the default mode for the LED Meter and Status Display. When active, all Input
module meters display the signal level of the source selected by the Meter function of
the LCD Menu System.
■
Status
When
Status
is pressed, the Input module meter displays module status information.
While in Status display, the labels to the left of the LEDs describe the LED function. From
the top down, these are:
Line
Chan path sourced from the Line Input
Stereo
Chan path assigned to the Stereo Mix bus
Track
The Track Assign is sourced from the Chan path
Aux 1-4
Aux 1 through 4 is sourced Pre or Post the Chan path
Mast
The Chan path is the Master of a fader group
1-2/13-14
Module is assigned to Track Out pairs 1/2 and 13/14
3-4/15-16
Module is assigned to Track Out pairs 3/4 and 15/16
5-6/17-18
Module is assigned to Track Out pairs 5/6 and 17/18
7-8/19-20
Module is assigned to Track Out pairs 7/8 and 19/20
9-10/21-22
Module is assigned to Track Out pairs 9/10 and 21/22
11-12/23-24
Module is assigned to Track Out pairs 11/12 and 23/24
Tape
Mix path sourced from the Tape Input
Stereo
Mix path assigned to the Stereo Mix bus
Track
The Track Assign is sourced from the Mix path
Aux 5-8
Aux 5 through 8 is sourced Pre or Post the Mix path
Mast
The Mix path is the Master of a fader group
Status is a timed function. After a preset amount of time the meter display returns to
Level mode. Pressing
Status
twice locks the Meter Display in Status mode. Pressing
Level
or
Function
returns the meter display to normal operation
■
Function
When
Function
is pressed, the module LED Meter and Status Displays are used to
display a module’s state
for one function only
. This provides a way to quickly view the
switch state of a single function on all modules.
Function is a timed display. After a preset amount of time the meter display returns to
Level mode. Pressing
Function
twice locks the Meter Display in Function mode.
Pressing
Level
or
Status
returns the meter display to normal operation. The timeout can
be changed in the
MASTER
option of MISC Menu of the LCD Menu System.
STATUS 18R
Operation and Maintenance Manual
Section 3 - Controls and Indicators
August 1999
3 - 22
Function
Status
Level
Meter
Display
Meter Display
12
6
12
24
36
48
∞
6
0
–
+
Tape
Stereo
Track
Aux 5-8
Mast
13–14
1–2
3–4
15–16
5–6
17–18
7–8
19–20
9–10
21–22
11–12
23–24
CHAN
Line
Stereo
Track
Aux 1-4
Mast
8
6
4
2
0
2
4
6
8
10
12
16
20
24
28
36
+
–