STATUS 18R
Operation and Maintenance Manual
Appendix A - LCD Menu Reference
August 1999
A - 15
Meter
Solo
Group
Recall
Automation
Misc
SWITCH UNDO MKCUE OPTS
ALLRD RECORD PLAY SAFE
Selects Switch Automation
display.
If mixing, kills current pass.
Confirms after timecode stops.
If not mixing, cycles passes in
Mix Stack.
Captures current time code
into Cue Registers A–Z.
Selects Automation options,
including Auto Button
Assignment and Auto Glide
On/Off.
Places all paths in
the Read mode.
Selects the Mix Record
mode. Toggles with
SAFE
.
Changes the Automation
from Record to Play mode.
Selects the Mix Safe mode
on the PC. Toggles with
REC
.
Automation
Main Menu
Meter
Solo
Group
Recall
Automation
Misc
TOGGLE MATCH LVMOM LEAVE
READ UPDATE WRITE ISOLT
Selects the Read mode for
all paths.
Interlocks with
WRITE
,
UPDT
, and
ISOL
.
Selects Update mode for all
paths.
Interlocks with
READ
,
WRITE
, and
ISOL
.
Selects the Write mode for
all paths.
Interlocks with
READ
,
UPDT
,
and
ISOL
.
Selects the Isolate mode for
all paths.
Interlocks with
READ
,
WRITE
, and
UPDT
.
Automation
SWITCH
Press
Automation
to Return to
Main Menu.