Patch the calibrated meter to the console’s Right Stereo bus output. Set the
VR20 on the Analog Master board until the meter reads +4 dBu.
6.4.3 Calibrating Stereo Mechanical Meters
The calibration trim pot for the stereo mechanical meters is accessed by removing the
two plastic “plugs” on the rear of the meter bridge. The trim pot for each meter is located
on a PC board inside the top of the access hole. Adjust the trim pot so the meter reads
“0” VU when the Stereo Bus output is +4 dBu. There is no adjustment for the Stereo
LED meters.
STATUS 18R
Operation and Maintenance Manual
Section 6 - Alignment and Maintenance
August 1999
6 - 5
Aux Master Pots
Analog Master PC Board
Stereo Bus VR19 and VR20