5.6.5 Isolating Switches
Eagle automation can record both fader and switch moves to data. In this step, we will
isolate the console switches so that only faders are written to data.
When a fader or switch is isolated, it doesn’t read or write automation data. It operates
like a normal fader or switch.
To isolate the console switches:
1.
On the console Master Section, press
Automation
to display the Automation
LCD menu.
2.
Press the button above
SWITCH
to display switch automation options.
3.
Press
ISOLT
to isolate all switches from automation.
4.
Press
Automation
to return to the main automation menu.
Meter
Solo
Group
Recall
Automation
Misc
One
Many
F1
None Selected
F2
F3
SoftKey
Toggle
Module
Undo
Set
Transparent
Swap Last
State
Auto
Select
Shift
TOGGLE MATCH LVMOM LEAVE
READ UPDATE WRITE ISOLT
Locks Leave On
untill Read is pressed
or end of pass
Enables
Momentary Leave
Sets all switches
to Write
Isolates
all switches
from automation
Sets Toggle or
Match Write entry
Sets all switches
to Update
Sets all switches
to Read
STATUS 18R
Operation and Maintenance Manual
Section 5 - Eagle Automation
August 1999