5.4.2 SWITCH Menu
The Switch menu is used for global control of switch automation. The function buttons
above and below the LCD execute the function shown on the display. These functions are:
•
TOGGLE
:
Sets switch update entry to Toggle mode.
•
MATCH
:
Sets switch update entry to Match mode.
•
LVMOM
:
Leave Momentary. Allows a single switch to leave Update Write mode.
•
LEAVE
:
Locks Leave mode On so that a number of switches can leave Update Write
mode.
•
READ
:
Sets all switches to Read mode.
•
UPDATE
:
Sets all switches to Update mode.
•
WRITE
:
Sets all switches to Write mode.
•
ISOLT
:
Isolates switches from reading or writing data.
5.4.3 OPTS (Options) Menu
The
OPTS
(Options) menu provides control of additional automation functions. The
function buttons above and below the LCD execute the function shown on the display.
These functions are:
•
-BUTN-
:
Pressing the button underneath
BUTN
selects the fader that the
Auto
button
affects.
•
-STYLE-
:
Pressing the button underneath
STYLE
sequences through
Auto
button
mode styles.
•
ENDPS
:
Selects the End Pass Fader Mode screen.
•
GLIDE
:
Toggles fader glide On and Off.
•
ARCH
:
Pressing
ARCH
saves the current mix to disk and increments the Write mix
number.
•
AUTREC
:
Toggles Auto Record On and Off.
Meter
Solo
Group
Recall
Automation
Misc
One
Many
F1
None Selected
F2
F3
SoftKey
Toggle
Module
Undo
Set
Transparent
Swap Last
State
Auto
Select
Shift
-BUTN-STYLE- ENDPS GLIDE
LOWER WRITE ARCH AUTREC
Toggles Auto Glide
On and Off
Selects the End Pass
Fader Mode display
Saves current mix
to disk
Toggles Auto Record
On and Off
Sets mode style for
Upper and Lower path
Assigns Auto button
to Upper or Lower path
Meter
Solo
Group
Recall
Automation
Misc
One
Many
F1
None Selected
F2
F3
SoftKey
Toggle
Module
Undo
Set
Transparent
Swap Last
State
Auto
Select
Shift
TOGGLE MATCH LVMOM LEAVE
READ UPDATE WRITE ISOLT
Locks Leave On
untill Read is pressed
or end of pass
Enables
Momentary Leave
Sets all switches
to Write
Isolates
all switches
from automation
Sets Toggle or
Match Write entry
Sets all switches
to Update
Sets all switches
to Read
Section 5 - Eagle Automation
STATUS 18R
Operation and Maintenance Manual
5 - 8
August 1999