Installing the Switch
81
3. Compare what you see to the following table:
4. Access the CMC and configure the
uboot
parameters.
See
“Access the CMC From the Serial Management Port” on page 82
Related Information
■
Switch Administration
, checking status LEDs
■
“Check the Power Supply Status LEDs” on page 80
■
“Check the Fabric Card Status LEDs” on page 96
■
“Check the Line Card Status LEDs” on page 103
■
“Check the CXP Connector Status LEDs” on page 115
Accessing the CMC
With power applied, you can now access the CMCs by performing these tasks in the
following order.
Glyph
Name
Color
State and Meaning
OK
Green
On – CMC is operating normally.
Off – No power is being supplied to the CMC.
Flashing – CMC is inactive status as the backup CMC.
Attention
Amber
On – A fault or critical error has been detected.
Off – Normal operation.
Flashing – No function.
Ready-to-Remove
Blue
On – CMC has been deactivated and is ready to be removed.
Off – Do not remove.
Flashing – No function.
Step
Description
Links
1.
Access the CMC from the serial
management port.
“Access the CMC From the Serial
Management Port” on page 82
2.
Set the initial
uboot
parameters.
“Set the Initial UBoot Parameters” on
page 83
3.
Access the CMC from the network
management port.
Содержание Sun Datacenter InfiniBand Switch 648
Страница 1: ...Sun Datacenter InfiniBand Switch 648 Installation Guide Part No 820 7738 12 May 2010 Revision A ...
Страница 8: ...viii Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 134: ...124 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 140: ...130 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...