80
Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
▼
Check the Power Supply Status LEDs
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. Visually inspect the power supply status LEDs.
3. Compare what you see to the following table.
4. Verify the CMC status LEDs indicate a normal start up.
The OK LED should be lit and the Attention LED should be unlit. See
Related Information
■
Switch Administration
, checking status LEDs
■
“Check the CMC Status LEDs” on page 80
■
“Check the Fabric Card Status LEDs” on page 96
■
“Check the Line Card Status LEDs” on page 103
■
“Check the CXP Connector Status LEDs” on page 115
▼
Check the CMC Status LEDs
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. Visually inspect the CMC status LEDs.
Glyph
Name
Color
State and Meaning
OK
Green
On – Power supply enabled, 12 VDC is supplied.
Off – No input voltage.
Flashing – Power supply disabled, 12 VDC is not supplied.
Attention
Amber
On – Fault detected, 12 VDC shut down.
Off – Normal operation.
Flashing – No function.
Содержание Sun Datacenter InfiniBand Switch 648
Страница 1: ...Sun Datacenter InfiniBand Switch 648 Installation Guide Part No 820 7738 12 May 2010 Revision A ...
Страница 8: ...viii Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 134: ...124 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 140: ...130 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...