Installing the Switch
73
2. Lift the line card from the work surface and orient it horizontally, with the link
LEDs across the bottom.
3. Insert the line card into the chassis at slot 0.
Ensure that the line card is square to the chassis and not skewed.
Note –
Once the line card is about halfway into the slot, it is no longer necessary to
bear the weight of the line card.
4. Continue to slide the line card in, maintaining a squared orientation.
When you feel resistance, stop.
5. While pressing the line card in with one hand, rotate the retainer bolts
clockwise by hand so that they engage.
When you feel resistance in the retainer bolts, stop.
6. Using a 20 mm socket and ratchet, turn the left retainer bolt 1/4 turn clockwise.