Measurement Settings
70
ZG User’s Manual
Changing the Edge Level and Edge Direction
Set the edge level and edge direction when selecting edge-related measurement items.
This setting is enabled only in the EXP mode.
FUN mode-[MEAS]-[SENS]-[TASK1 to 8]-[CUSTOM]-[EDGELV]
Changing the edge level
Selecting the edge direction
Set the edge search direction.
Setting value
Description
Edge level
Align the line of the edge level with the edge to be detected.
The range differs according to the CCD mode.
Standard and high-resolution mode: 0 to 399
High-speed mode:
0 to 199
Setting value
Description
→
Forward direction
The “1st edge from the left” in the area is searched for.
←
Reverse direction
The “1st edge from the right” in the area is searched for.