I/O Settings
90
ZG User’s Manual
I/O Settings
Setting Analog Output Conditions
This section describes the settings required for analog output of the current measurement
result.
Assignment of Analog Output
Set the assignment to the analog output wire. Only one task can be assigned for analog
output when multiple tasks are set.
FUN mode-[I/O]-[ANALOG]-[TASK]
Setting value
Description
OFF
Analog output is not performed.
TASK1, TASK2, TASK3,
TASK4, TASK5, TASK6,
TASK7, TASK8
The measurement value of the task selected here is analog-output
from the Controller. (default value: TASK1)