Mounting and Connecting Devices
25
ZG User’s Manual
1
BEFORE USE
Measurement range
< Mounting for diffuse reflection measurement >
< Mounting for regular reflection measurement >
The beam diameter and measurement range (width) between the NEAR/FAR ends are nominal
values, and are not to be used as guaranteed values.
Measurement
center distance
Measurement range
(height)
Measurement
range (width)
Beam diameter
100 mm
±12 mm
NEAR end: 20 mm
220 µm
CENTER:
22 mm
60 µm
FAR end:
24 mm
220 µm
Measurement
center distance
Measurement range
(height)
Measurement
range (width)
Beam diameter
94 mm
±10 mm
NEAR end: 20 mm
220 µm
CENTER:
22 mm
60 µm
FAR end:
24 mm
220 µm
NE
AR
end
+
12
mm
C
ENTE
R
0
mm
F
AR
end
-
12
mm
Measurement
center
d
i
stance
100
mm
Spread
ang
l
e
10°
Ang
l
e
of
i
ntersect
i
on
25°
:
Measurement
range
: I
rrad
i
at
i
on
range
20
mm
22
mm
2
4
mm
Measurement
range
(w
i
dth)
Beam
d
i
ameter
NE
AR
end
+
10
mm
C
ENTE
R
0
mm
F
AR
end
-
10
mm
Measurement
center
d
i
stance
9
4
mm
Spread
ang
l
e
10°
Ang
l
e
of
i
ntersect
i
on
25°
:
Measurement
range
: I
rrad
i
at
i
on
range
20
mm
22
mm
2
4
mm
Measurement
range
(w
i
dth)
Beam
d
i
ameter
Important
Содержание ZG -
Страница 12: ...10 ZG User s Manual MEMO ...
Страница 44: ...Overview of Settings and Measurement 42 ZG User s Manual MEMO ...
Страница 60: ...Functions Operations Used during Operation RUN Mode 58 ZG User s Manual MEMO ...
Страница 110: ...System Settings 108 ZG User s Manual MEMO ...
Страница 156: ...Serial Communication 154 ZG User s Manual MEMO ...
Страница 206: ...204 ZG User s Manual MEMO ...
Страница 207: ...205 ZG User s Manual 5 APPENDICES MEMO ...
Страница 208: ...206 ZG User s Manual MEMO ...