Measurement Settings
79
ZG User’s Manual
3
FUNCTION SETTINGS
Setting the smoothing function
Changes in data are smoothed out using the intermediate values of adjacent data.
Smoothing is performed in the “width direction (X-axis direction).” This setting is effective
in filtering noise such as spikes.
FUN mode-[MEAS]-[IMAGE]-[PROFILE]-[SMOOTH]
Averaging is not performed for the data on the right edge because the required number of
samples cannot be obtained.
Setting value
Description
OFF, LOW, MID, HIGH
Sets the smoothing strength.
(default value: LOW)
N
ot
e
[ 1]
OK
[64]
OK
MEAS/AVERAGE
[LOW]
OK
MEAS/SMOOTH
[HIGH]
OK
MEAS/SMOOTH