I/O Settings
93
ZG User’s Manual
3
FUNCTION SETTINGS
Correcting Analog Output Values
Discrepancies may occur between the analog output current (or voltage) values set on
the Controller and the actual current (or voltage) values measured due to the conditions
for the connected external device or other factors. The analog output correction function
can be used to correct this discrepancy.
The output values are corrected by entering the correction value for the current (or
voltage) values for any two points. (default value: OFF)
Range: -999 to 999
Set scaling beforehand, and select current output or voltage output. Also, connect the analog
output wire to an external ammeter or voltmeter.
FUN mode-[I/O]-[ANALOG]-[ADJUST]-[ON]
1
Move the cursor to the numerical
value by the
↑
/
↓
key, and press
the SET key.
2
Select the output value of MIN by
the
↑
/
↓
key, and press the SET key
twice.
Important
I/O/OUT MIN
[
4mA
]
OK
I/
O
/
OU
T
M
IN
[ 4
mA
]
O
K
Содержание ZG -
Страница 12: ...10 ZG User s Manual MEMO ...
Страница 44: ...Overview of Settings and Measurement 42 ZG User s Manual MEMO ...
Страница 60: ...Functions Operations Used during Operation RUN Mode 58 ZG User s Manual MEMO ...
Страница 110: ...System Settings 108 ZG User s Manual MEMO ...
Страница 156: ...Serial Communication 154 ZG User s Manual MEMO ...
Страница 206: ...204 ZG User s Manual MEMO ...
Страница 207: ...205 ZG User s Manual 5 APPENDICES MEMO ...
Страница 208: ...206 ZG User s Manual MEMO ...