Serial Communication
148
ZG User’s Manual
Parameter List
DATAGET Command
Judgment value parameters
DATASET Command
Parameters at image adjustment
Sensitivity adjustment
Parameter
Unit No.
Parameter No.
Output Range
Judgment value
47+10 * (task-1)
40
0: Error, 1: LOW, 2: PASS,
3: HIGH
Parameter
Unit No.
Parameter No.
Setting range
Mode selection
1
2
0: MULTI, 1: AUTO, 2: FIXED
MULTI HIGH
1
5
1 to 320
MULTI LOW
1
6
1 to 320
MULTI STEP
1
4
0: Fine adjusting, 1: Normal,
2: Rough adjustment
AUTO HIGH
1
7
1 to 320
AUTO LOW
1
8
1 to 320
FIXED
1
9
0 to 320 (0: laser out)